If you run a water utility and you rely only on the federal government's public vulnerability lists to decide what to patch, a new industry index says you are seeing about half the picture. Exposure-management firm Securin has published Water Supply Chain Watch. It is an index of 236 vendors that supply equipment and software to US drinking-water, wastewater and industrial-water systems. According to reporting by The Register, the index found almost twice as many vulnerabilities in that vendor base as public records show. Those include 20 flaws that are being exploited but do not appear in CISA's Known Exploited Vulnerabilities (KEV) catalog.
The study's other finding may matter more to anyone defending a plant. Many of the real intrusions it describes did not use a software bug. Attackers got in through default or missing passwords, controllers left reachable from the internet, and badly secured cellular modems.
A note on sourcing: Securin's own report page is a JavaScript-rendered shell that we could not read. The figures below come from three outlets that covered the index: The Register, LavX News and the aggregator Mallory. Read the counts as Securin's claims as those outlets reported them.
What Securin measured
Securin compared its own vulnerability data for the 236 water-sector vendors against public sources: CISA, the EPA, the FBI and WaterISAC, the sector's information-sharing center. The Register and LavX both report the same data cutoffs. CISA industrial control system (ICS) advisories were counted through November 20, and the KEV catalog through November 23.
For scale, the federal government has issued 4,014 ICS security advisories and cataloged 1,792 known-exploited vulnerabilities, according to both outlets. An ICS advisory is CISA's notice that a product used in industrial operations, such as a programmable logic controller (PLC), a human-machine interface or an industrial router, has a security flaw. The KEV catalog is CISA's list of flaws with evidence of exploitation in the wild. Federal civilian agencies must patch KEV entries by set deadlines, and many private organizations use the list as their "patch this first" queue.
That second use is why the 20-flaw gap matters. If an exploited bug is missing from KEV, a team that triages only by KEV will not move it to the front of the line. The coverage reviewed does not list the 20 flaws individually, so we cannot name them here.
A handful of vendors dominate
The Register reports that federal water advisories are at their highest level since 2020. Five vendors account for 191 of the 376 advisories tagged as water-relevant:
- Rockwell Automation: 58
- Advantech: 48
- Schneider Electric: 35
- Siemens: 26
- ABB: 24
Securin's researchers noted that the volume of advisories is not a reliable predictor of real-world attacks. One detail stands out. Advantech, the second-ranked vendor, has the most critical-rated vulnerabilities of any vendor in the index, yet none of the CVEs in its advisories are in KEV, according to The Register. A defender sorting only by "known exploited" would treat that vendor's backlog as low priority, even though it carries the highest critical-severity count.
Advisory counts are a poor guide to risk
The clearest example in the reporting is Unitronics. The PLC maker had only two water-tagged advisories in the dataset. Yet at least 75 of its controllers were compromised between November 2023 and January 2024 by attackers taking advantage of default or missing passwords, The Register reports. No software exploit was needed to get in.
The same theme runs through more recent activity. The Register reports that intrusions in July, which security researchers suspect were the work of Iran-linked attackers, targeted more than 100 water systems, with incidents reported across at least 12 states. That attribution is the researchers' suspicion as relayed by the reporting, not a confirmed finding.
Mallory's summary and The Register add exposure numbers. According to Securin, 791 Rockwell MicroLogix 1400 controllers across multiple US industries were exposed to the internet as of November 17. Research by Forescout, cited by Securin, found that about 70 percent of exposed US Rockwell controllers sit on mobile carrier networks, where poorly secured cellular modems can give attackers an entry point. These modems are often installed by third-party contractors and frequently go undocumented, The Register notes.
Mallory also notes that the reporting does not establish any outages, water-quality changes or financial losses from these intrusions, and that the exposure counts should not be read as counts of compromised utilities. That is worth keeping in mind. "Accessed" is not the same as "poisoned," and the index measures exposure and vulnerability, not harm.
Why the public lists fall behind
None of the three outlets say exactly how Securin found the extra vulnerabilities, and the coverage does not explain why the public lists miss them. Securin's CEO, Srinivas Mukkamala, framed the practical consequence in a statement quoted by The Register: water utilities are spending time and money fixing the vulnerabilities they are told to worry about, while attackers get in through equipment nobody knew was connected or passwords nobody bothered to change.
What It Means for Defenders
Who is affected: Municipal and private drinking-water and wastewater operators, industrial facilities that treat their own process water, and the integrators and contractors who install and maintain their control systems. If your plant uses PLCs, HMIs or remote telemetry from any of the 236 vendors in Securin's index, and especially from the five most-advised vendors above, this applies to you.
Don't triage by KEV alone. KEV is a floor, not a ceiling. According to the reporting, at least 20 exploited flaws in water-sector products are missing from it. Track vendor advisories directly for the products you actually run, and weigh CVSS severity and network exposure alongside "known exploited" status. Advantech's critical-but-not-in-KEV backlog is the obvious test case.
Fix the non-bug problems first. The intrusions described in this coverage mostly succeeded without software exploits. The priorities reported from the study are:
- Inventory every cellular modem. Pay particular attention to modems installed by contractors, which are often missing from the utility's own asset records. If you don't know a modem exists, you can't secure it.
- Remove controllers from direct internet exposure. A PLC should not answer connections from the public internet. With 791 MicroLogix 1400 units reported exposed as of November 17 (across multiple industries), check your own address space and your carrier-assigned IPs, not just your wired WAN.
- Route remote access through gateways protected by multi-factor authentication (MFA). Vendors and integrators who need remote access should come in through a controlled gateway that requires MFA, not through a modem wired straight to a controller.
Rotate and set credentials. The Unitronics compromises used default or missing passwords. Audit every controller and HMI for factory-default credentials or no password at all, and change them. Make credential setup part of your commissioning checklist for any new or replaced device.
Patch what the vendors have fixed. The coverage reviewed does not list specific fixed firmware versions for the flaws in the index. For Rockwell, Advantech, Schneider Electric, Siemens and ABB products in your environment, check each vendor's advisory page and CISA's ICS advisories for the specific models you run. Then schedule updates during maintenance windows, alongside the exposure fixes above.
Ask your vendors and integrators. If Securin's count is right, roughly half of the known vulnerabilities in this supply chain are not in public federal records. Ask your suppliers directly which vulnerabilities affect the products you've bought, and whether any are being exploited. Put that question in contract renewals.